[docs]class DpControl: """DpControl commands group definition. 4 total commands, 0 Sub-groups, 4 group commands""" def __init__(self, core: Core, parent): self._core = core self._base = CommandsGroup("dpControl", core, parent)
[docs] def get_enable(self) -> bool: """SCPI: CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:ENABle \n Snippet: value: bool = driver.configure.connection.pswitched.dpControl.get_enable() \n Enables/disables downlink power control. \n :return: enable: OFF | ON """ response = self._core.io.query_str('CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:ENABle?') return Conversions.str_to_bool(response)
[docs] def set_enable(self, enable: bool) -> None: """SCPI: CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:ENABle \n Snippet: driver.configure.connection.pswitched.dpControl.set_enable(enable = False) \n Enables/disables downlink power control. \n :param enable: OFF | ON """ param = Conversions.bool_to_str(enable) self._core.io.write(f'CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:ENABle {param}')
# noinspection PyTypeChecker
[docs] def get_p(self) -> enums.PswPowerReduction: """SCPI: CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:P \n Snippet: value: enums.PswPowerReduction = driver.configure.connection.pswitched.dpControl.get_p() \n Defines a power reduction relative to BCCH. \n :return: p_0: DB0 | DB2 | DB4 | DB6 | DB8 | DB10 | DB12 | DB14 | DB16 | DB18 | DB20 | DB22 | DB24 | DB26 | DB28 | DB30 0 dB to 30 dB """ response = self._core.io.query_str('CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:P?') return Conversions.str_to_scalar_enum(response, enums.PswPowerReduction)
[docs] def set_p(self, p_0: enums.PswPowerReduction) -> None: """SCPI: CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:P \n Snippet: driver.configure.connection.pswitched.dpControl.set_p(p_0 = enums.PswPowerReduction.DB0) \n Defines a power reduction relative to BCCH. \n :param p_0: DB0 | DB2 | DB4 | DB6 | DB8 | DB10 | DB12 | DB14 | DB16 | DB18 | DB20 | DB22 | DB24 | DB26 | DB28 | DB30 0 dB to 30 dB """ param = Conversions.enum_scalar_to_str(p_0, enums.PswPowerReduction) self._core.io.write(f'CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:P {param}')
# noinspection PyTypeChecker
[docs] def get_pmode(self) -> enums.PowerReductionMode: """SCPI: CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:PMODe \n Snippet: value: enums.PowerReductionMode = driver.configure.connection.pswitched.dpControl.get_pmode() \n Defines the power reduction mode of the downlink power control. \n :return: pr_mode: PMA | PMB PMA: power reduction mode A PMB: power reduction mode B """ response = self._core.io.query_str('CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:PMODe?') return Conversions.str_to_scalar_enum(response, enums.PowerReductionMode)
[docs] def set_pmode(self, pr_mode: enums.PowerReductionMode) -> None: """SCPI: CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:PMODe \n Snippet: driver.configure.connection.pswitched.dpControl.set_pmode(pr_mode = enums.PowerReductionMode.PMA) \n Defines the power reduction mode of the downlink power control. \n :param pr_mode: PMA | PMB PMA: power reduction mode A PMB: power reduction mode B """ param = Conversions.enum_scalar_to_str(pr_mode, enums.PowerReductionMode) self._core.io.write(f'CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:PMODe {param}')
# noinspection PyTypeChecker
[docs] def get_pfield(self) -> enums.PowerReductionField: """SCPI: CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:PFIeld \n Snippet: value: enums.PowerReductionField = driver.configure.connection.pswitched.dpControl.get_pfield() \n Indicates the power level reduction of the current RLC block. \n :return: pr_field: DB0 | DB3 | DB7 | NUSable DB0: 0 dB to 3 dB (excluded) less than BCCH level - P0 DB3: 3 dB to 7dB (excluded) less than BCCH level - P0 DB7: 7 dB to 10 dB less than BCCH level - P0 NUSable: not usable - MS has to ignore PR field """ response = self._core.io.query_str('CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:PFIeld?') return Conversions.str_to_scalar_enum(response, enums.PowerReductionField)
[docs] def set_pfield(self, pr_field: enums.PowerReductionField) -> None: """SCPI: CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:PFIeld \n Snippet: driver.configure.connection.pswitched.dpControl.set_pfield(pr_field = enums.PowerReductionField.DB0) \n Indicates the power level reduction of the current RLC block. \n :param pr_field: DB0 | DB3 | DB7 | NUSable DB0: 0 dB to 3 dB (excluded) less than BCCH level - P0 DB3: 3 dB to 7dB (excluded) less than BCCH level - P0 DB7: 7 dB to 10 dB less than BCCH level - P0 NUSable: not usable - MS has to ignore PR field """ param = Conversions.enum_scalar_to_str(pr_field, enums.PowerReductionField) self._core.io.write(f'CONFigure:GSM:SIGNaling<Instance>:CONNection:PSWitched:DPControl:PFIeld {param}')