Limit

SCPI Commands

CONFigure:GSM:SIGNaling<Instance>:BER:PSWitched:LIMit:CIIBits
CONFigure:GSM:SIGNaling<Instance>:BER:PSWitched:LIMit:DBLer
CONFigure:GSM:SIGNaling<Instance>:BER:PSWitched:LIMit:USFBler
class Limit[source]

Limit commands group definition. 3 total commands, 0 Sub-groups, 3 group commands

get_cii_bits()float[source]
# SCPI: CONFigure:GSM:SIGNaling<Instance>:BER:PSWitched:LIMit:CIIBits
value: float = driver.configure.ber.pswitched.limit.get_cii_bits()

Specifies upper limits for the BER class II bit results of the BER PS measurement.

return

class_2_bits: Range: 0 % to 100 %, Unit: %

get_dbler()float[source]
# SCPI: CONFigure:GSM:SIGNaling<Instance>:BER:PSWitched:LIMit:DBLer
value: float = driver.configure.ber.pswitched.limit.get_dbler()

Specifies upper limits for the DBLER results of the BER PS measurement.

return

dbler: Range: 0 % to 100 %, Unit: %

get_usf_bler()float[source]
# SCPI: CONFigure:GSM:SIGNaling<Instance>:BER:PSWitched:LIMit:USFBler
value: float = driver.configure.ber.pswitched.limit.get_usf_bler()

Specifies upper limits for the USF BLER results of the BER PS measurement.

return

usf_bler: Range: 0 % to 100 %, Unit: %

set_cii_bits(class_2_bits: float)None[source]
# SCPI: CONFigure:GSM:SIGNaling<Instance>:BER:PSWitched:LIMit:CIIBits
driver.configure.ber.pswitched.limit.set_cii_bits(class_2_bits = 1.0)

Specifies upper limits for the BER class II bit results of the BER PS measurement.

param class_2_bits

Range: 0 % to 100 %, Unit: %

set_dbler(dbler: float)None[source]
# SCPI: CONFigure:GSM:SIGNaling<Instance>:BER:PSWitched:LIMit:DBLer
driver.configure.ber.pswitched.limit.set_dbler(dbler = 1.0)

Specifies upper limits for the DBLER results of the BER PS measurement.

param dbler

Range: 0 % to 100 %, Unit: %

set_usf_bler(usf_bler: float)None[source]
# SCPI: CONFigure:GSM:SIGNaling<Instance>:BER:PSWitched:LIMit:USFBler
driver.configure.ber.pswitched.limit.set_usf_bler(usf_bler = 1.0)

Specifies upper limits for the USF BLER results of the BER PS measurement.

param usf_bler

Range: 0 % to 100 %, Unit: %